Model NO.
WNS2-1.0-Y. Q
Installation
Packaged Boiler
Structure
Fire Tube
Media
Steam
Water Circulation
Natural Circulation
Drum Placement
Horizontal Boiler
Pressure
Low Pressure
Manufacturing Level
B
Burning Style
Chamber Combustion Boiler
Usage
Industrial
Light Oil Steam Boiler
Horizontal Light Oil Steam Boiler
Steam Capacity
0.5-15t/H
Rated Working Pressure
0.7-3.8MPa
Cladding Material
SUS304, 316L
Pump Type
Vertical Centrifugal
Lead Time
20-120days/Set
Certificate
CE
Transport Package
Naked & Plywood Case
Specification
Steam capacity from 0.5-15 ton/h
Trademark
FUTURE
Origin
Zhangjiagang-China
HS Code
84021900
Production Capacity
5sets/Month

Product Description


Horizontal Light Oil Steam Boiler
1) Steam Capacity: 0.5-10Ton/h
2) Pressure: 8-38bar
3) Available Fuel: Light Diesel

I. Detailed Product Description:
   The WNS series of horizontal internal-combustion boiler is the boiler hull type horizontal three pass internal-combustion boiler designed by our technical professionals according to advanced technology both at home and abroad, combined with practical experience.

II. The main advantages of Heavy Oil Steam Boiler
1. Safe, Stable and Powerful.
2. The boiler uses clean energy to satisfy the national environmental policy. The boiler room is clean and no pollution.
3. The boiler runs automatically. Fewer stokers are needed.
4. The boiler room accounts a small space. The construction investment can be decreased.
5. The boiler starts up quickly. It can reach the rated working condition within 20 minutes.
6. Combustion apparatus are made of imported and original products. The quality is good and maintenance is less.
7. CE marking as per Pressure Equipment Directive (PED 97/23/EC)Specifications as options, and ASME Code is also available.

III. Technical Parameters:


 
         Model
Item
Unit WNS0.5-0.8-Y.Q WNS0.75-0.8-Y.Q WNS1-1.0-Y.Q WNS1.5-1.0-Y.Q WNS2-1.0-Y.Q WNS3-1.0-Y.Q
Rated steam capacity t/h 0.5 0.75 1 1.5 2 3
Rated working pressure MPa 0.8 (1.0, 1.25, 1.6) 1.0 (1.25, 1.6, 2.0)
Saturated steam temperature ºC 175 (184, 193, 204) 184 (193, 204, 213)
Heating surface
(with economizer)
m2 14.3 19.6 25 36 58.8 98.6
Fuel
Consumption     
Light diesel kg/h 34 51 68 102 136 204
Heavy fuel oil Kg/h 35.36 53 69.7 104 139.4 210
Natural gas Nm3/h 37 56 74 111 148 222
LPG Nm3/h 13.4 19.5 26 39.1 56 85
Main steam outlet valve diameter PN 16 (20, 25)
DN 40 50 50 65 65 80
Air vent valve diameter PN 16 (20, 25)
DN 20 20 25 25 25 25
Safety valve diameter PN 16 (20, 25)
DN 40 40 50 2×40 2×40 2×40
Water inlet diameter PN 16 (20, 25)
DN 25 25 25 32 40 40
Blow-down valve diameter PN 16 (20, 25)
DN 40 40 40 40 50 50
Overall dimension L mm 3550 3870 4010 4530 5260 5780
W mm 1900 2000 2100 2380 2600 3100
H mm 2800 3030 3200 3500 3780 3950
Max. transportation size of boiler
(LxWxH)
mm 3040x1420 x1900 3200x1630 x2000 3450x1900 x2040 3910x2000 x2260 4450x2200 x2450 4890x2340 x2520
Net Weight Ton 3.6 4.1 4.5 6.3 8.5 11.6
                   
 
Item          Model Unit WNS4-1.25-Y.Q WNS5-1.25-Y.Q WNS6-1.25-Y.Q WNS8-1.25-Y.Q WNS10-1.25-Y.Q
Rated steam capacity t/h 4 5 6 8 10
Rated working pressure MPa 1.25 (1.6, 2.0, 2.5, 3.8)
Saturated steam temperature ºC 193 (204, 213, 224, 247)
Heating surface
(with economizer)
m2 111.8 163.1 181.17 190.77 232.16
Fuel
Consumption
Light diesel kg/h 272 340 408 540 680
Heavy fuel oil Kg/h 278.8 348.4 418.1 553 686.4
Natural gas Nm3/h 296 370 440 592 740
LPG Nm3/h 113 130 145 226 260
Main steam outlet valve diameter PN 16 (20, 25, 40)
DN 100 100 125 125 150
Air vent valve diameter PN 16 (20, 25, 40)
DN 40 40 40 50 50
Safety valve diameter PN 16 (20, 25, 40)
DN 2×50 80 / 50 80 / 50 2×80 2×80
Water inlet diameter PN 16 (20, 25, 40)
DN 40 40 40 50 50
Blow-down valve diameter PN 16 (20, 25, 40)
DN 2×40 2×50 2×50 2×50 2×50
Overall
dimension
L mm 6410 6910 7330 7920 8400
W mm 3250 3320 3400 3560 3790
H mm 4120 4230 4300 4900 5530
Max. transportation size of boiler
(LxWxH)
mm 5120x2390 x2660 5590x2520
x2800
5760x2630
x2950
6680x2750
x3090
7290x2860 x3200
Net weight Ton 13.8 17.1 19.5 23.6 28.8
                 
 
Statement:
1) All of the above values are based on low heat value of light diesel at 10200kcal/kg, low heat value of heavy fuel oil at 9850kcal/kg, low heat value of natural gas(NG) at 8500kcal/Nm³ and low heat value of LPG at 25600kcal/Nm³ as the standard calculations.
2) The above table for the standard configuration of the boiler. According to the special requirements of users, we can provide other evaporation, working pressure or other boilers under special circumstances.
3) The above data is for reference only, the specific calculation data according to drawings or calculation sheets.
 

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now
Contact Supplier